The Helman Group HM1525 Manuel d'utilisateur Page 20

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 27
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 19
Chapter
5
System
Trouble-
shooting
Guide
HT-400 Sensor Ohm Readings
Green-Black 350 ohms
Red-White 350 ohms
All other color combinations 266 ohms
All colors to Ground open
Shield to Ground open
Electrical Specifications:
Type of input Strain Gage (350 ohm, 700 ohm)
Input Impedance 10k
Display Resolution Up to .0025% of full scale
Overall Module Accuracy .01% of full scale
Module Update Time 10 µsec
Number of Channels 2 (isolated)
A/D Conversion Method Successive Approximation - 16 bit
Normal Mode Rejection:
(between +/- input) 116DB CMRR
Amplifier Bandwidth 200 kHz
Calibration Software Selectable
Isolation: 500 VDC continuous between inputs
and chassis ground, and between input
and backplane
LED indicators 2 LED's for Power and Alarm
Recommended Cable Strain Gage Cable (Helm part number 6117)
Terminal Strip 16-pin removable
Operating Temperatures 0°C to 60°C (32°F to 140°F)
Hazardous Environment
Classification Class 1 Division 2 Hazardous Environment
Trim Jumper
Located at Bottom
Left Corner of Module
Black Jumper
Factory Jumper. Removing this
Jumper will cause module to
Become unstable.
Page 5-1
Vue de la page 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 26 27

Commentaires sur ces manuels

Pas de commentaire